  1. So, if I understand correctly, the tool applies a hotfix to the recursion issue? One that is not covered in the current version of OpenComputers?
  2. Okay, It’s been a while since I used this. What are the required and recommended ingame hadware? The first post is a little short on specifics. What is up with the default text?
  3. @Crack3dC0d3 which problem? Failure to finish calibrating or suspending an failing to resume?
  4. What are you using for steam transport?
  5. Oooh. Good news is it seems to be consistent and repeatable...bad news is that it seems to be repeatable.
  6. @afr33sl4ve That's part of why the gelid works better between the rods! also if you have Immersive Engineering, check out the fluid outlet. It works like the old floodgate, great for deploying fluids.
  7. @afr33sl4ve If you did build it this way, seriously consider swapping the two liquids! http://br.sidoh.org/#reactor-design?length=16&width=16&height=46&activelyCooled=false&controlRodInsertion=97&layout=O14EOEXCXCXCXCXCXCXC2ECXCXCXCXCXCXCX2EXCXCXCXCXCXCXC2ECXCXCXCXCXCXCX2EXCXCXCXCXCXCXC2ECXCXCXCXCXCXCX2EXCXCXCXCXCXCXC2ECXCXCXCXCXCXCX2EXCXCXCXCXCXCXC2ECXCXCXCXCXCXCX2EXCXCXCXCXCXCXC2ECXCXCXCXCXCXCX2EXCXCXCXCXCXCXC2ECXCXCXCXCXCXCXEO14EO
  8. @Sellerino possibly the server you assembled has a higher maximum number of peripherals it can recognise. I can't swear to it though, haven't worked with the server rack yet. Currently working on designing a Star Trek style main engineering room with a draconic reactor and storage orb at the top and bottom and the draconic power transfer system lighting up a "warp core" between them. Will post pics when I get it working.
  9. @daraku_dakara Interesting, thanks!
  10. BrisingrAerowing I can say with certainty that Extreme Reactors is not capped at 2000mB per tick. 2000 B per tick maybe. Try checking the max throughput of your steam transport. Make sure you are supplying plenty of water to the reactor as well. How many turbines do you have connected? If you only have 1 it will try to make exactly 2000mB. 2 turbines will set a target of 4000mB, 3 : 6000, etc.
  11. @simcye The only way I can see to get your system to run smoothly is to do a separate open computer for each turbine/reactor set or like @XyFreak implied take all of your steam and unify it. I'd suggest three OC units personally.
  12. Does your reactor design look like this, or like this?
  13. @NamesReed is it keeping your storage full? Also try using the command line to set the steam target to 2000.
  14. Good point. There are very few mods capable of moving Buckets/tick.
  15. looks like it's only outputting 3.5B of steam per tick. did you connect a fluid sink while calibrating the reactor?
  16. Is there a way to force a recalibration of a passive reactor?
×
×